MTL4561 2channel loop-powered, for fire and smoke detectors
MTL4561 2channel loop-powered, for fire and smoke detectors
MTL4561 product specification as below for your reference.
MTL4561 2channel loop-powered, for fire and smoke detectors
MTL4561 –
MTL5561 FIRE AND SMOKE DETECTOR INTERFACE 2-channel The MTLx561 is a
loop-powered 2–channel interface for use with conventional fire and smoke
detectors located in hazardous areas. In operation, the triggering of a
detector causes a corresponding change in the safe–area current. The unit
features reverse input polarity protection.
SPECIFICATION
MTL4561 2channel loop-powered, for fire and smoke detectors
See also common
specification
Number of channels
Two, fully floating, loop powered
Location of fire and smoke
detectors
Zone 0, IIC, T4–6 hazardous area if suitably
certified
Div. 1, Group A, hazardous area
Input voltage
6 to 30V dc
Current range
1 to 40mA, nominal
Quiescent safe–area current
at 20°C
(hazardous–area terminals open circuit)
< 400µA at Vin = 24V per channel
Integral input polarity
protection
Input circuit protected against reverse polarity
Minimum output voltage Vout
at 20°C
For Vin ≤ 25V: Vout = Vin – (0.38 x current in mA)
– 2V
For Vin > 25V: Vout = 22.5V – (0.35 x current in
mA)
Maximum output voltage
28V from 300Ω
Transfer accuracy at 20°C
Better than 400µA
Temperature drift
< 4µA/°C ( 0°C to 60°C)
< 15µA/°C (–20°C to 0°C)
Response time to step input
Settles to within 5% of final value within 1.5ms
Power dissipation within
unit
0.7W maximum at 24V with 40mA signal (each channel)
0.9W maximum at 30V with 40mA signal (each channel)
Safety description for each
channel
Uo=28V Io=93mA Po=0.65W Um = 253V rms or dc
Other related models for MTL4500 range as below
MTL4561 2channel loop-powered, for fire and smoke detectors
MTL4501-SR
MTL4504
MTL4510
MTL4510B
MTL4511
MTL4513
MTL4514D
MTL4514_B
MTL4516
MTL4516C
MTL4517
MTL4521
MTL4521L
MTL4523
MTL4523L
MTL4523R
MTL4523V-VL
MTL4524
MTL4524S
MTL4525
MTL4526
MTL4541
MTL4541A
MTL4541AS
MTL4541B
MTL4541P
MTL4541S
MTL4541T
MTL4544
MTL4544A
MTL4544AS
MTL4544B
MTL4544D
MTL4544S
MTL4546
MTL4546C
MTL4546S
MTL4546Y
MTL4549
MTL4549C
MTL4549Y
MTL4573
MTL4575
MTL4576-RTD
MTL4576-THC
MTL4581
MTL4582B
MTL4531
MTL4532
MTL4561
MTL4599
MTL4599N
MTL4561 2channel loop-powered, for fire and smoke detectors
If you have any other question about MTL4561, please feel free to contact me here!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报