Product overview
MTL4526 safety isolators 2 channel switch operated relay England origin product
MTL4526 2 channel switch operated relay England origin product
MTL4526 product specification as below
MTL4526 safety isolators 2 channel switch operated relay England origin product
MTL4526 –
MTL5526 SWITCH-OPERATED RELAY 2–channel IS–output The MTLx526 enables two
separate IS circuits in a hazardous area to be contact controlled by one or two,
on/off, control signals in a safe area. Applications include the calibration of
strain–gauge bridges; changing the polarity (and thereby the tone) of an IS
sounder; the testing of IS fire alarms; and the transfer of safe-area signals
into an annunciator with IS input terminals not segregated from each other. The
output–relay contacts are certified as non–energy–storing apparatus, and can be
connected to any IS circuit without further certification, provided that
separate IS circuits are such that they would remain safe if connected
together.
SPECIFICATION
MTL4526 safety isolators 2 channel switch operated relay England origin product
See also common
specification
Number of
channels
Two, fully
floating
Location of
control circuit
Safe area
Input/output
characteristics
Contact/Logic
mode
(Inputs
suitable for switch contacts, an open–collector transistor
or logic drive)
Relay energised
if < 450Ω or < 1V applied
Relay
de–energised if > 5kΩ or > 2V applied (35V max.)
Loop powered
mode
Relay energised
if >20V
Relay
de-energised if <17V
Power supply
failure protection
Relays
de–energised if supply fails
Response time
25ms nominal
Contacts
(suitable for connection to IS circuits)
1–pole
changeover per channel
Contact rating
250V ac,
limited to 40V dc for IS applications, 2A
(reactive loads
must be suppressed)
Contact life
expectancy
2 x 107
operations at maximum IS load
Relay drive
(see switch setting table)
Choice of
"loop-powered" or "contact/logic" control, for both
channels, by
switch selection. A further switch option ("1in2out")
enables either
input, in contact/logic mode, to activate both
outputs.
LED indicators
Green: power
indication
Yellow: two:
output status, on when relay energised
Power
requirement, Vs
41mA at 20V dc
44mA at 24V dc
60mA at 35V dc
Power
dissipation within unit
1.1W maximum at
24V
Safety
description (each channel)
Non-energy–storing
apparatus: relay contacts may be connected
to any IS
circuit without further consideration
MTL4526 safety isolators 2 channel switch operated relay England origin product
Other related models for MTL4500 range as below
MTL4526 safety isolators 2 channel switch operated relay England origin product
MTL4501-SR
MTL4504
MTL4510
MTL4510B
MTL4511
MTL4513
MTL4514D
MTL4514_B
MTL4516
MTL4516C
MTL4517
MTL4521
MTL4521L
MTL4523
MTL4523L
MTL4523R
MTL4523V-VL
MTL4524
MTL4524S
MTL4525
MTL4526
MTL4541
MTL4541A
MTL4541AS
MTL4541B
MTL4541P
MTL4541S
MTL4541T
MTL4544
MTL4544A
MTL4544AS
MTL4544B
MTL4544D
MTL4544S
MTL4546
MTL4546C
MTL4546S
MTL4546Y
MTL4549
MTL4549C
MTL4549Y
MTL4573
MTL4575
MTL4576-RTD
MTL4576-THC
MTL4581
MTL4582B
MTL4531
MTL4532
MTL4561
MTL4599
MTL4599N
MTL4526 safety isolators 2 channel switch operated relay England origin product
If you have any other question about MTL4526, please feel free to contact me here!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报