Product overview
MTL4523V-VL safe isolator Solenoid/Alarm driver with voltage control
MTL4523V-VL Solenoid/Alarm driver with voltage control
MTL4523V-VL product specification as below for your reference.
MTL4523V-VL safe isolator Solenoid/Alarm driver with voltage control
MTL4523V/VL –
MTL5523V/VL SOLENOID/ALARM DRIVER with line fault detection, IIC
With the
MTLx523V/VL interface, an on/off device in a hazardous area can be controlled
by a voltage signal in the safe area. It is suitable for driving loads such as
solenoids. Line fault detection (LFD), which operates irrespective of the
output state, is signalled by a safe-area solid-state switch which energises if
a field line is open or short– circuited. Earth fault detection can be provided
by connecting an MTL4220 earth leakage detector to terminal 3.
SPECIFICATION
MTL4523V-VL safe isolator Solenoid/Alarm driver with voltage control
See also common
specification
Number of
channels
One
Location of
load
Zone 0, IIC,
T4–6 hazardous area if suitably certified
Div. 1, Group
A, hazardous location
Minimum output
voltage Equivalent output circuit
(MTLx523V)
22.2
22.2
13.6
Minimum output
voltage Equivalent output circuit
(MTLx523VL)
Output current
(mA) 48
Output
voltage
(V)
22.2V minimum
232Ω maximum
Current limit:
48mA
22.2
11.1
Hazardous-area
output (MTLx523V)
Minimum output
voltage: 13.6V at 48mA
Maximum output
voltage: 24V from 180Ω
Maximum
off-state output voltage: 4V from 180Ω
Current limit:
48mA minimum
Hazardous-area
output (MTLx523VL)
Minimum output
voltage: 11.1V at 48mA
Maximum output
voltage: 24V from 232Ω
Maximum
off-state output voltage: 4V from 232Ω
Current limit:
48mA minimum
Output ripple
< 0.5% of
maximum output, peak to peak
Control input
Suitable for
24V logic drive
Output turns on
if > 18V applied across control input
Output turns
off if < 5V applied across control input
Maximum control
input voltage: 28V
Maximum control
system output leakage current: 0.5mA
Response time
Output within
10% of final value within 100ms
Line fault
detection (LFD)
Open or short
circuit in field cabling energises solid state
line-fault
signal.
LFD transistor
is switched off, provided that the field circuit impedance is >
55Ω and <
4kΩ.
Line fault
signal characteristics
Maximum
off-state voltage: 35V
Maximum
off-state leakage current: 10µA
Maximum
on-state voltage drop: 2V
Maximum
on-state current: 50mA
LED indicators
Green: power
indication
Yellow: output
status, on when output active
Red: LFD
indication, on when line fault detected
Maximum current
consumption
100mA at 24V dc
Power
dissipation within unit
1.2W with
typical solenoid valve, output on
2.0W worst case
Safety
description (MTLx523V)
Vo=25V Io=147mA
Po= 0.92W Um = 253V rms or dc
Safety
description (MTLx523VL)
Vo=25V Io=108mA
Po= 0.68W Um = 253V rms or dc
MTL4523V-VL safe isolator Solenoid/Alarm driver with voltage control
Other related models for MTL4500 series as below
MTL4523V-VL safe isolator Solenoid/Alarm driver with voltage control
MTL4501-SR
MTL4504
MTL4510
MTL4510B
MTL4511
MTL4513
MTL4514D
MTL4514_B
MTL4516
MTL4516C
MTL4517
MTL4521
MTL4521L
MTL4523
MTL4523L
MTL4523R
MTL4523V-VL
MTL4524
MTL4524S
MTL4525
MTL4526
MTL4541
MTL4541A
MTL4541AS
MTL4541B
MTL4541P
MTL4541S
MTL4541T
MTL4544
MTL4544A
MTL4544AS
MTL4544B
MTL4544D
MTL4544S
MTL4546
MTL4546C
MTL4546S
MTL4546Y
MTL4549
MTL4549C
MTL4549Y
MTL4573
MTL4575
MTL4576-RTD
MTL4576-THC
MTL4581
MTL4582B
MTL4531
MTL4532
MTL4561
MTL4599
MTL4599N
MTL4523V-VL safe isolator Solenoid/Alarm driver with voltage control
If you have any other question about MTL4523V-VL, please feel free to contact me here!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报