MTL4600 Isolation Barrier MTL4604
Building on the base of the MTL4500 range, MTL4600 range offers a high level of signal isolation for installations where multiple loops on a common connection are not desirable.
Signal isolation provides excellent protection against surges, common faults and noisy environments. It also eliminates the risk of earth loops between different areas of the plant, which, if not isolated, can cause significant errors or failures under fault conditions.
MTL4600 isolators are fully compatible with all existing backplanes used with the MTL4500 range and many control systems. The form factor and signal types offer the user a common approach for both IS and non-IS signals.
3-port isolation as standard
Highest module/channel packing densities
Low power dissipation
Quick install and release mechanism
Multi-channel I/O modules
Broken line and earth-fault protection
For Intrinsic Safety applications, see the MTL4500 range.
MTL4600 Isolation Barrier MTL4604
Isolation—protecting your system Designing your plant with good clean earth systems is not always possible. Poor ground conductivity,large process areas and heavy electrical machinery, all contribute to increased noise. This noise is induced or conducted into adjacent wiring,which in turn degrades the quality of the signals passing through the cables. Without isolation this noise is superimposed on the process signal causing a loss of accuracy, poor control and possibly failures or false trips.
Many control systems, PLCs and safety systems do not have full isolation between channels. In compact well defined plant layouts this is acceptable, but these are not always guaranteed. To avoid interference between channels, isolation is the solution.
The MTL4600 range of isolators offer reduced risk and greater protection to the system, with all the advantages of a common design
approach for both IS and non-IS signals.
System Solutions
Building on the base of the MTL4500 range of solutions, the MTL4600 offers a high level of signal isolation for installations where multiple loops on a common connection are not desirable.
Signal isolation provides excellent protection against surges, common faults and noisy environments. It also eliminates the risk of earth loops between different areas of the plant, which, if not isolated, can cause significant errors or failures under fault conditions.
MTL4600 isolators are fully compatible with all existing backplanes used with MTL4500 range and many control systems. The form factor and signal types offer the user a common approach for both IS and non-IS signals.
MTL4600 Isolation Barrier MTL4604
models
1. Digital Input
MTL4604
MTL4610
MTL4611
MTL4614
MTL4614D
MTL4616
MTL4617
MTL4619H
MTL4619L
2. Digital Output
MTL4621
MTL4623
MTL4623L
MTL4623R
MTL4624
MTL4624S
MTL4626
MTL4627
MTL4628
3. Analogue Input
MTL4641
MTL4641A
MTL4641AS
MTL4641S
MTL4644
MTL4644A
MTL4644AS
MTL4644D
MTL4644S
4. Analogue Output
MTL4646
MTL4646Y
MTL4649
MTL4649Y
5. Temperature Input
MTL4675
MTL4676-RTD
MTL4676-THC
6. Pulse Input
MTL4632
MTL4600 Isolation Barrier MTL4604
If you have any interest, pls feel free to contact me as below
Jackie Ma
HONGKONG XIEYUAN TECH CO., LIMITED
Add:7-A16,Caishen Commercial Plaza,Hangkou Railway Station,Wuhan, China
M:86-(WhatsApp & Telegram) | T:+86-27-85887732 | F:86-27-85309780
Email:Jackie@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报