Rosemount 8800D Series Vortex Flowmeter
HART
and FOUNDATION
Fieldbus Protocols
All welded, non-clog design provides maximum performance, reliability and enhanced safety by
eliminating ports and gaskets. No seals, just steel.
CriticalProcess
Vortex eliminates bypass piping and optimizes safety during maintenance.
SIL 2/3 Capable: IEC 61508 certified by an accredited 3rd party agency for use in safety instrumented
systems up to SIL 3.
Available with optional multivariable output. Internal temperature compensation provides cost-effective
saturated steam and liquid mass flow measurement.
Adaptive Digital Signal Processing (ADSP) provides vibration immunity and flow range optimization.
Reducer
Vortex extends the measurable flow range, reduces installation costs, and minimizes project
risk.
Simplified troubleshooting through device diagnostics and meter verification.
Available in wafer, flanged, dual, reducer and high pressure designs.
Rosemount 8800D Series Vortex Flowmeter
The Rosemount 8800D delivers reliability, safety, and maximum process availability
Rosemount Reliability—The Rosemount 8800D Vortex
eliminates impulse lines, ports, and gaskets to improve
reliability.
Rosemount 8800D Series Vortex Flowmeter
Non-clog Design—Unique all welded, gasket-free
construction which has no ports or crevices that can clog.
SIL 2/3 Capable - The Rosemount 8800D Vortex is certified by
an accredited 3rd part agency for use in safety instrumented
systems up to SIL 3 (minimum requirement of single use
or SIL 2 and redundant use [1oo2] for SIL 3).
Vibration Immunity—Mass balancing of the sensor system,
and Adaptive Digital Signal Processing (ADSP) provide
vibration immunity.
Replaceable Sensor—The sensor is isolated from the process
and can be replaced without breaking the process seal. All line
sizes use the same sensor design allowing a single spare to
serve every meter.
Simplified Troubleshooting—Device Diagnostics enable field
verification of meter electronics and sensor without process
shutdown.
Rosemount 8800D Series Vortex Flowmeter
Eliminate bypass piping for critical process
installations
Traditional vortex installations in critical applications include a
bypass line to allow process fluid to be re-directed around the
vortex flow meter during routine sensor maintenance.
Rosemount's unique non-wetted sensor can be installed
without bypass piping, even in the most difficult process
environments.
Improve process availability
Eliminate the need to shut down the process during routine
maintenance and meter verification.
Enhances safety in hazardous process fluid
applications
A needle valve enables access to the sensor cavity to verify that
no process fluid is present.
Available in Flanged, Reducer, and Dual Vortex meter designs in
1- through 12-in. meter body sizes for ASME B16.5 flange
connections.
Available in 40 mm through 300 mm meter body sizes for EN
1092-1 and JIS B2220 flange connections.
Rosemount 8800D Series Vortex Flowmeter
We have good price on yokogawa DCS,yokogawa transmitter,yokogawa analyzer yokogawa flowmeter.ABB(Pressure transmitter,analyzer,Low voltage products),
Honeywell(pressure transmitter,analyzer,DCS,Gas detector),Rosemount(pressure transmitter,analyzer,flowmeter),MTL( safety barrier),P+F( safety barrier),Norgren(Values,Regulator)
Schneider,Weidmuller terminal blocks,Festo,Pnoenix contactor etc.
Also We have Emerson 475 field communicators in ready stock, such as 475FP1EKLUGMTS, 475HP1EKLUGMTS, 475HP1EKLUGMT, 475HP1ENA9GMTS
and some more, new and original from Emerson Germany.Any inquiry about our scope,pls feel free to contact me.