Product Material
Home >>> Product Class >>> Yokogawa >>> Yokogawa Process Analyzers
易展国际 >>> 展馆展区 >>> Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A
[

Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A

]
sendmsg
Product Name: Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A
Product Model: ZR202G-100-S-E-N-C-R-M-E-A
Manufacturer: Yokogawa
file:No Related Documents


Product Description

Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A

Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A

Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A


Yokogawa Integral Oxygen Analyzer ZR202G

The EXAxt ZR202 transmitter / detector combines benefits of the ZR402 remote analyzer and the ZR22 detector into an intelligent, rebuildable, low-cost measurement device for in-situ humidity measurement. This smart probe features a local LCD display and infrared push-button operation for local adjustment of the instrument and calibration control. HART communication protocol allows easy configuration of the instrument as well as up to the second information on all process variables and diagnostic tools. The Yokogawa ZR202 smart probe offers customers a lower cost of product ownership by significantly reducing installation costs from tubing, wiring and conduit. Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A;

 

Yokogawa Integral Oxygen Analyzer ZR202G

Infra-red switch operation;HART communication for configuration

Integrated automatic calibration available

Integral design can reduce installation costs

Allows replacement of Zirconia cell and heater in the field

Can measure either oxygen concentration or humidity


Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A

Specifications


Measurement object Oxygen concentration in combustion exhaust gas and mixed gas.
Measurement system Zirconia system
Oxygen concentration 0.01 to 100 vol% O2
Output signal 4 to 20 mA DC, two points (maximum load resistance 550Ω)
Measurement range Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol%O2), or partial range
Digital communication (HART) 250 to 550 Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure -5 to +250 kPa
Sample gas temperature 0 to 700°C (Probe only)
700 to 1400°C (with 0.15m probe and High Temperature Probe Adapter)
Probe length 0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6,4.2, 4.8, 5.4 m
Contact output Four points (one is fail-safe, normally open)
Contact input Two points
Calibration Method ; zero/span calibration
Calibration mode ;
automatic, semi-automatic and manual (All are operated interactively with an LCD touch screen)
Construction of detector Non-explosion proof. Equivalent to NEMA4X/IP66
Construction of converter Outdoor installation. Equivalent to NEMA4X/IP66
Ambient temperature Probe: -20 to 150°C
Converter: -20 to 55°C
Power supply 85 to 264 V AC; 45 to 66 Hz
Repeatability ±0.5% Maximum value of set range
Linearity ±1% Maximum value of set range
Drift ±2% Maximum value of set range/month
Response time

90% response within 5 sec


Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A

Models:

Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

ZR22G-100-S-A-C-T-T-E-A

ZR22G-040-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A

ZR22G-040-S-A-E-T-T-E-A 

ZR22G-070-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A/SCT

ZR40H-T-T-A

K9473XJ

K9471UA

ZR22G- 070-S-A-E-T-T-E-A  

ZR402G- T-E-E-A

ZR402G-T-E-E-A

ZR22G-070-S-A-E-T-T-E-A/CV

X9473XJ

ZR22G-070-S-A-E-T-T-E-A

ZR402G-M-E-E-A/SCT

ZR22G-150-S-A-E-T-M-E-A/SCT

ZR22G-040-S-A-C-T-T-E-A/ SCT

ZR22G-040-S-A-C-T-T-E-A/SCT

ZR22G-040-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A

K9473XG

ZR40H-T-T-A

ZR22G-040-S-A-C-T-T-E-A

ZR22G-100-S-C-T-T-E-A/CV

ZR402G-M-E-E-A

ZR40H-T-T-A

ZR402G-M-E-E-A/H/SCT

ZR22G-040-C-C-C-T-T-E-A

ZR40H-T-T-A

ZR22G-040-S-A-C-T-T-E-A

ZR402G-T-E-E-A

ZR22G-070-S-A-E-T-T-E-A

ZR22G-070-S-A-E-T-T-E-A/CV/F1/SCT

ZR22G-100-S-A-E-T-M-E-A/CV/SCT,

ZR402G-M-E-E-A/SCT, 

ZA8F-A,

K9473XK,

G7001ZC,

G7014XF,

E7044KF,

ZR22G-100-S-B-E-T-T-E-A/CV/SCT

ZR40H-T-T-A

ZR22G-100-S-A-E-T-M-E-A/CV/SCT/F1

ZO21R-L-100-J-B

ZR402G-M-E-E-A/SCT   

ZR22G-100-S-A-E-T-M-E-A/CV/SCT/F1  
ZA8F-A                                                      
K9473XK                                              

ZR22G-070-S-C-E-R-P-E-A/CV

ZR402G-P-E-E-A/SCT/C3

ZO21S-7-E-A

E7050BA

G7016XH

ZR22G-015-S-Q-C-R-M-E-A/SCT

ZR22G-040-S-K-C-T-M-E-A

ZO21P-H-A-100-E*B

E7046EC

ZR402G-T-E-E-A

ZR22G-040-S-B-C-T-T-E-A

ZR202G-100-S-E-N-C-R-M-E-A

ZR202G-070-S-E-N-C-R-M-E-A

Yokogawa Integral Oxygen Analyzer ZR202G-100-S-E-N-C-R-M-E-A


Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报


Product Search
Contact Us
Browse by Category
Copyright@ 2003-2025   HONGKONG XIEYUAN TECH CO.,LIMITED