MTL5582 RESISTANCE ISOLATOR MTL 5582 RESISTANCE ISOLATOR
MTL5582 RESISTANCE ISOLATOR MTL 5582 RESISTANCE ISOLATOR
The MTL5582 connects to a 2-, 3-, or 4-wire resistance temperature
device (RTD) or other resistance located in a hazardous area, isolates
it and repeats the resistance to a monitoring system in the safe area.
The module is intended typically (but not exclusively) for use with
Pt100 3-wire RTDs. Switches enable selection of 2-, 3-, or 4-wire RTD
connection. The MTL5582 should be considered as an alternative, nonconfigurable
MTL5575, for use in RTD applications where a resistance
input is preferred or needed instead of 4/20mA. The design is notable
for its ease of use and repeatability. The number of wires which can
be connected on the safe-area side of the unit is independent of the
number of wires which can be connected on the hazardous-area side.
The module drives upscale in the case of open circuit detection. Note
that this module is not suitable for use with measurement systems
where the resistance input channels are multiplexed.
SPECIFICATION
MTL5582 RESISTANCE ISOLATOR MTL 5582 RESISTANCE ISOLATOR
See also common specification
Number of channels
One
Location of RTD
Zone 0, IIC, T4 hazardous area
Div. 1, Group A, hazardous location
Resistance source
2-, 3-, or 4-wire* RTDs to BS 1904/DIN 43760 (100Ω at 0°C)
*user selectable by switches (factory set for 3-wire)
Resistance range
10Ω to 400Ω
RTD excitation current
200μA nominal
MTL5582 RESISTANCE ISOLATOR MTL 5582 RESISTANCE ISOLATOR
Output configuration
2, 3 or 4 wires (independent of mode selected for hazardous area
terminals)
Output range
10Ω to 400Ω (from a 100μA to 5mA source)
Temperature drift
±10mΩ/C° typical (0.01%/°C @ 100Ω)
Response time
To within 4% of final value within 1s
Not suitable for muliplexed input cards
Safety drive on open-circuit sensor
Upscale to 420Ω nominal
Transfer accuracy@20°C
<0.15Ω at excitation current 1 - 5mA
<0.25Ω at excitation current 0.5 - 1mA
LED indicator
MTL5582 RESISTANCE ISOLATOR MTL 5582 RESISTANCE ISOLATOR
Green: power indication
Power requirements, Vs
33mA at 24V
35mA at 20V
28mA at 35V
Maximum power dissipation within unit
0.8W at 24V
1.0W at 35V
Safety description
Terminals 1 and 3
Uo = 1.2V Io = 4mA Po = 1.2mW Um = 253V rms or dc
Non-energy-storing apparatus ≤ 1.5V, ≤ 0.1A, ≤ 25mW; can
be connected without further certification into any IS loop with
an open circuit voltage < 5V.
Terminals 1 and 3 and 4 and 5
Uo = 6.6V Io = 42mA Po = 69mW
MTL5582 RESISTANCE ISOLATOR MTL 5582 RESISTANCE ISOLATOR
MTL5501-SR FAIL-SAFE SWITCH/PROXIMITY DETECTOR INTERFACE WITH LFD
MTL5510 SWITCH/ PROXIMITY DETECTOR INTERFACE 4-CHANNEL, DIGITAL INPUT
MTL5510B SWITCH/ PROXIMITY DETECTOR INTERFACE 4-CHANNEL, MULTI-FUNCTION, DIGITAL INPUT
MTL5511 SWITCH/ PROXIMITY DETECTOR INTERFACE 1-CHANNEL, WITH LINE FAULT DETECTION
MTL5513 SWITCH/ PROXIMITY DETECTOR INTERFACE 2-CHANNEL, LINE FAULT DETECTION, PHASE REVERSAL
MTL5514 SWITCH/ PROXIMITY DETECTOR INTERFACE 1-CHANNEL, LINE FAULT DETECTION, PHASE REVERSAL
MTL5514D SWITCH/ PROXIMITY DETECTOR INTERFACE 1-CHANNEL, DUAL OUTPUT, LFD, PHASE REVERSAL
MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 2-CHANNEL, WITH LINE FAULT DETECTION
MTL5517 SWITCH/ PROXIMITY DETECTOR INTERFACE 2-CHANNEL, LINE FAULT DETECTION, PHASE REVERSAL
MTL5521 SOLENOID/ ALARM DRIVER LOOP-POWERED, IIC
MTL5522 SOLENOID/ALARM DRIVER LOOP-POWERED, IIB
MTL5523 SOLENOID/ALARM DRIVER WITH LINE FAULT DETECTION, IIC
MTL5523V - VL SOLENOID/ALARM DRIVER WITH LINE FAULT DETECTION, IIC
MTL5524 SOLENOID/ALARM DRIVER SWITCH OPERATED WITH OVERRIDE, IIC
MTL5525 SOLENOID/ALARM DRIVER SWITCH OPERATED WITH OVERRIDE, IIC, LOW POWER
MTL5526 SWITCH-OPERATED RELAY 2–CHANNEL IS–OUTPUT
MTL5541 REPEATER POWER SUPPLY 4/20MA, HART
, 2- OR 3-WIRE TRANSMITTERS
MTL5541A CURRENT REPEATER 4/20MA PASSIVE I/P FOR HART
TRANSMITTERS
MTL5541AS CURRENT REPEATER 4/20MA PASSIVE I/P FOR HART
TRANSMITTERS
MTL5541S REPEATER POWER SUPPLY 4/20MA, HART
, 2- OR 3-WIRE TRANSMITTERS
MTL5544 REPEATER POWER SUPPLY 2-CHANNEL, 4/20MA, HART
, 2- OR 3- WIRE TRANSMITTERS
MTL5544A CURRENT REPEATER 4/20MA PASSIVE I/P FOR HART
TRANSMITTERS
MTL5544AS CURRENT REPEATER 4/20MA PASSIVE I/P FOR HART
TRANSMITTERS
MTL5544D REPEATER POWER SUPPLY SINGLE CHANNEL, 4/20MA, HART
FOR 2- OR 3-WIRE TRANSMITTERS, TWO OUTPUTS
MTL5544S REPEATER POWER SUPPLY 2-CHANNEL, 4/20MA, HART
, 2- OR 3- WIRE TRANSMITTERS
MTL5546 ISOLATING DRIVER FOR 4–20MA HART
VALVE POSITIONERS WITH LINE FAULT DETECTION
MTL5546Y ISOLATING DRIVER FOR 4–20MA HART
VALVE POSITIONERS WITH LINE FAULT DETECTION
MTL5549 ISOLATING DRIVER TWO-CHANNEL, FOR 4–20MA, HART
VALVE POSITIONERS WITH LINE FAULT DETECTION
MTL5549Y ISOLATING DRIVER TWO-CHANNEL, FOR 4–20MA, HART
VALVE POSITIONERS WITH LINE FAULT DETECTION
MTL5575 TEMPERATURE CONVERTER THC OR RTD INPUT + ALARM
MTL5576-RTD TEMPERATURE CONVERTER RTD/POTENTIOMETER INPUT, 2-CHANNEL
MTL5576-THC TEMPERATURE CONVERTER MV/THC INPUT, 2-CHANNEL
MTL5581 MILLIVOLT/THERMOCOUPLE ISOLATOR FOR LOW-LEVEL SIGNALS
MTL5582 RESISTANCE ISOLATOR TO REPEAT RTD SIGNALS
MTL5531 VIBRATION TRANSDUCER INTERFACE
MTL5532 PULSE ISOLATOR PULSE & 4/20MA CURRENT OUTPUTS
MTL5533 VIBRATION TRANSDUCER INTERFACE 2-CHANNEL
MTL5561 FIRE AND SMOKE DETECTOR INTERFACE 2-CHANNEL
MPA5500 A.C. POWER ADAPTOR
MTL5599 DUMMY ISOLATOR
MTL5991 24V DC POWER SUPPLY
MTL5599 DUMMY ISOLATOR MTL 5599 DUMMY ISOLATOR
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报