Honeywell SPXCDALMNX gas detector Sensepoint XCD SPXCDALMNX
Overview
Honeywell SPXCDALMNX gas detector Sensepoint XCD SPXCDALMNX
Sensepoint XCD is designed for use in potentially explosive atmospheres. As such, installation
should follow national guidelines using suitable mechanically protected cable and glands or
conduit. Use 0.5mm2 (20AWG) to 2.5mm2 (~13AWG) cross sectional area cable as needed
to ensure minimum operating voltage at the detector, depending on installed cable length.
Cable diameter should be selected to maintain the minimum required voltage for the longest
installed cable length under maximum power.
Honeywell SPXCDALMNX gas detector Sensepoint XCD SPXCDALMNX
The Sensepoint XCD transmitter may be wired in either Current Sink or Current Source configuration. These two options are offered to allow greater flexibility in the type of control system that it can be
used with. Sink/Source is selectable via the switch located on the back side of the display module; accessible by removing the display module during installation/commissioning.
Sensepoint XCD uses three instantly recognisable ‘traffic light’ colours to indicate its status. The large tri-colour backlit LCD is steady green to indicate normal operation,flashes yellow to indicate a fault/warning
and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.
Honeywell SPXCDALMNX gas detector Sensepoint XCD SPXCDALMNX
The Sensepoint XCD transmitter has an integral mounting plate consisting of four mounting holes
on the transmitter body. The transmitter may be fixed directly to a surface mounting, or to a
horizontal or vertical pipe/structure, 40.0-80.0mm (1.6 to 3.1") in diameter/cross section.
The pipe mounting bracket accessory (optional) may be used for this purpose.
User cable entries shown (2 x M20) are for ATEX/IECEx version enclosures. UL/c-UL versions
have 2 x ¾"NPT conduit entries. A suitable blanking plug is supplied which must be used to
seal any unused entry. The blanking plug must be suitably sealed to maintain the IP rating of
the detector
SPXCDALMFX SPXCDALMRX SPXCDALMPX SPXCDALMO1
SPXCDALMHX SPXCDALMCX SPXCDALMG1 SPXCDALMNX SPXCDALMB1 SPXCDALMB2 SPXCDASMFX SPXCDASMRX SPXCDASMPX SPXCDASMO1 SPXCDASMHX SPXCDASMCX SPXCDASMG1 SPXCDASMNX SPXCDASMB1 SPXCDASMB2
SPXCDALMFXM SPXCDALMRXM SPXCDALMPXM SPXCDALMO1M SPXCDALMHXM SPXCDALMCXM SPXCDALMG1M SPXCDALMNXM SPXCDALMB1M SPXCDALMB2M SPXCDASMFXM SPXCDASMRXM SPXCDASMPXM SPXCDASMO1M SPXCDASMHXM SPXCDASMCXM SPXCDASMG1M SPXCDASMNXM SPXCDASMB1M SPXCDASMB2M
SPXCDULNFX SPXCDULNRX SPXCDULNPX SPXCDULNO1 SPXCDULNHX SPXCDULNCX SPXCDULNG1 SPXCDULNNX SPXCDULNB1 SPXCDULNB2 SPXCDUSNFX SPXCDUSNRX SPXCDUSNPX SPXCDUSNO1 SPXCDUSNHX SPXCDUSNCX SPXCDUSNG1 SPXCDUSNNX SPXCDUSNB1 SPXCDUSNB2
SPXCDULNFXM SPXCDULNRXM SPXCDULNPXM SPXCDULNO1M SPXCDULNHXM SPXCDULNCXM SPXCDULNG1M SPXCDULNNXM SPXCDULNB1M SPXCDULNB2M SPXCDUSNFXM SPXCDUSNRXM SPXCDUSNPXM SPXCDUSNO1M SPXCDUSNHXM SPXCDUSNCXM SPXCDUSNG1M SPXCDUSNNXM SPXCDUSNB1M SPXCDUSNB2M
SPXCDALMTX4 SPXCDASMTX4 SPXCDULNTX4 SPXCDUSNTX4 SPXCDALMTX4M SPXCDASMTX4M SPXCDULNTX4M SPXCDUSNTX4M SPXCDALMRFD SPXCDASMRFD SPXCDULNRFD SPXCDUSNRFD SPXCDALMRFDM SPXCDASMRFDM PXCDULNRFDM SPXCDUSNRFDM SPXCDXSRFXSS SPXCDXSRRXSS SPXCDXSRPXSS SPXCDXSRB1SS
SPXCDXSRB2SS
If you have any interest on this product,pls feel free to contact me.
Contact Information
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86
Skype:Jackie@hkxytech.com
Telegram:+86
Phone:+86
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报