Yokogawa DY Vortex flowmeter DY015
Yokogawa DY Vortex flowmeter DY015
Description
The Yokogawa DY Vortex flowmeter combines
the field proven sensor and body assembly used in more than 400,000 units
installed worldwide with a unique and powerful combination of digital
technology that includes spectral signal processing (SSP), a Yokogawa
innovation. The digitalYEWFLO vortex flow meter is accurate and stable, even in
harsh process conditions, and has a highly reliable and robust design that
delivers improvements in plant efficiency and reduced operating costs;
Yokogawa DY Vortex flowmeter DY015
Advanced Self-diagnostics
Provides diagnostic messages on high
vibration environments, excessive flow fluctuations, and clogging or plugging
in the area around the shedder bar. Analysis of the process allows true
condition-based maintenance.
Combining Noise Reduction and Spectral
Signal Processing (SSP) to provide an accurate and stable measurement.
Yokogawa's digitalYEWFLO is simple to
integrate into your existing system.
Yokogawa DY Vortex flowmeter DY015
Yokogawa DY Vortex flowmeter
Model and Suffix Codes
Yokogawa Vortex Flowmeter DY
DY Vortex Flowmeter (Integral Type, Remote type detector)
Model
|
Suffix Codes
|
Description
|
DY015
DY025
DY040
DY050
DY080
DY100
DY150
DY200
DY250
DY300
|
……………………………
……………………………
……………………………
……………………………
……………………………
……………………………
……………………………
……………………………
……………………………
……………………………
|
Size 15 mm (1/2 inch)
Size 25 mm (1 inch)
Size 40 mm (1-1/2 inch)
Size 50 mm (2 inch)
Size 80 mm (3 inch)
Size 100 mm (4 inch)
Size 150 mm (6 inch)
Size 200 mm (8 inch)
Size 250 mm (10 inch)
Size 300 mm (12 inch)
|
Output
Signal
/Commu- nication
|
-D …………………………
-E …………………………
-J …………………………
-F …………………………
-N …………………………
|
4 to 20 mA DC, Pulse, BRAIN Communication
4 to 20 mA DC, Pulse, HART Communication*1
4 to 20 mA DC, Pulse,
HART 5/HART 7Communication *2
Digital communication
(FOUNDATION Fieldbusprotocol) *3
Remote type detector
|
Body
Material*8
|
A ………………………
B ………………………
X ………………………
|
JIS SCS14 A *4
ASTM CF8M *5
Others *6
|
Shedder bar
Material
*8
|
L ………………… E ………………… X …………………
|
Duplex Stainless Steel
Duplex Stainless Steel (for TIIS
Approval) Others*7
|
Process
Connection
*9
RF : Raised Face SF : Smooth Finish RJ : Ring Joint
|
AJ1 ….………..…
AJ2 ….………..…
AJ4 ….………..…
|
JIS 10 K Wafer JIS 20 K Wafer JIS 40 K Wafer
|
AA1 ….………..…
AA2 ….………..…
AA4 ….………..…
|
ANSI Class 150 Wafer
ANSI Class 300 Wafer
ANSI Class 600 Wafer
|
AD1 ….………..…
AD2 ….………..…
AD3 ….………..…
AD4 ….………..…
|
DIN PN10 Wafer DIN PN16 Wafer DIN
PN25Wafer DIN PN40 Wafer
|
BJ1 ….………..…
BJ2 ….………..…
BJ4 ….………..…
|
JIS 10K Flange(RF) JIS
20K Flange(RF) JIS 40KFlange(RF)
|
BA1 ….………..…
BA2 ….………..…
BA4 ….………..…
BA5 ….………..…
|
ANSI Class 150 Flange(RF) ANSI Class300 Flange(RF) ANSIClass 600 Flange(RF) ANSI Class 900Flange(RF)
|
BS1 ….………..…
BS2 ….………..…
BS4 ….………..…
BS5 ….………..…
|
ANSI Class 150 Flange(RF, SF)
ANSIClass 300
Flange(RF,SF) ANSI Class 600
Flange(RF, SF) ANSIClass 900 Flange(RF,SF)
|
BD1 ….………..…
BD2 ….………..…
BD3 ….………..…
BD4 ….………..…
|
DIN PN10 Flange(RF)
DIN PN16 Flange(RF) DIN
PN25 Flange(RF) DIN PN40 Flange(RF)
|
CA4 ….………..…
CA5 ….………..…
|
ANSI Class 600Flange(RJ)
ANSI Class 900Flange(RJ)
|
Electrical
Connection *10
|
-0………..........
-2……….......…
-4……….......…
|
JIS G 1/2 Female
ANSI 1/2 NPT Female*11
ISO M20X1.5 Female
|
Indicator
*12
|
D ………...… N……..........
|
With Indicator
None Indicator, Remote type detector
|
Options
|
/口
|
Refer to Option Specifications
|
|
|
|
|
|
|
|
|
|
Yokogawa DY Vortex flowmeter DY015
DY250-DALAJ1-0D
DY080-DALAA2-0D
DY080-DALAA1-0D
DY080-DALAJ4-0D
DY080-DALAJ2-0D
DY080-DALAJ1-0D
DY050-DALAA2-0D
DY050-DALAA1-0D
DY050-DALAJ4-0D
DY050-DALAJ2-0D
DY050-DALAJ1-0D
DY040-DALAA2-0D
DY040-DALAA1-0D
DY040-DALAJ4-0D
DY040-DALAJ2-0D
DY040-DALAJ1-0D
DY025-DALAA2-0D
DY025-DALAA1-0D
DY025-DALAJ4-0D
DY025-DALAJ2-0D
DY025-DALAJ1-0D
DY015-DALAA2-0D
DY015-DALAA1-0D
DY015-DALAJ4-0D
DY015-DALAJ2-0D
DY015-DALAJ1-0D
DY250-DALBA1-0D
DY250-DALBJ4-0D
DY250-DALBJ2-0D
DY250-DALBJ1-0D
DY080-DALCA5-0D
DY080-DALCA4-0D
DY080-DALBD4-0D
DY080-DALBD3-0D
DY080-DALBD1-0D
DY080-DALBS5-0D
DY080-DALBS4-0D
DY080-DALBS2-0D
DY080-DALBS1-0D
DY080-DALBA5-0D
DY080-DALBA4-0D
DY080-DALBA2-0D
DY080-DALBA1-0D
DY080-DALBJ4-0D
DY080-DALBJ2-0D
DY080-DALBJ1-0D
DY050-DALCA5-0D
DY050-DALCA4-0D
DY050-DALBD4-0D
DY050-DALBD3-0D
DY050-DALBD2-0D
DY050-DALBD1-0D
DY050-DALBS5-0D
DY050-DALBS4-0D
DY050-DALBS2-0D
DY050-DALBS1-0D
DY050-DALBA5-0D
DY050-DALBA4-0D
DY050-DALBA2-0D
DY050-DALBA1-0D
DY050-DALBJ4-0D
DY050-DALBJ2-0D
DY050-DALBJ1-0D
DY040-DALCA5-0D
DY040-DALCA4-0D
DY040-DALBD4-0D
DY040-DALBD3-0D
DY040-DALBD2-0D
DY040-DALBD1-0D
DY040-DALBS5-0D
DY040-DALBS4-0D
DY040-DALBS2-0D
DY040-DALBS1-0D
DY040-DALBA5-0D
DY040-DALBA4-0D
DY040-DALBA2-0D
DY040-DALBA1-0D
DY040-DALBJ4-0D
DY040-DALBJ2-0D
DY040-DALBJ1-0D
DY025-DALCA5-0D
DY025-DALCA4-0D
DY025-DALBD4-0D
DY025-DALBD3-0D
DY025-DALBD2-0D
DY025-DALBD1-0D
DY025-DALBS5-0D
DY025-DALBS4-0D
DY025-DALBS2-0D
DY025-DALBS1-0D
DY025-DALBA5-0D
DY025-DALBA4-0D
DY025-DALBA2-0D
DY025-DALBA1-0D
DY025-DALBJ2-0D
DY025-DALBJ1-0D
DY015-DALCA5-0D
DY015-DALCA4-0D
DY015-DALBD3-0D
DY015-DALBD2-0D
DY015-DALBD1-0D
DY015-DALBS5-0D
DY015-DALBS4-0D
DY015-DALBS2-0D
DY015-DALBS1-0D
DY015-DALBA5-0D
DY015-DALBA4-0D
DY015-DALBA2-0D
DY015-DALBA1-0D
DY015-DALBJ4-0D
DY015-DALBJ4-0D
DY015-DALBJ1-0D
DY250-DALAD4-0D
DY250-DALAD3-0D
DY080-DALAD4-0D
DY080-DALAD3-0D
DY050-DALAD4-0D
DY050-DALAD3-0D
DY040-DALAD4-0D
DY040-DALAD3-0D
DY025-DALAD4-0D
DY025-DALAD3-0D
DY015-DALAD4-0D
DY015-DALAD3-0D
DY250-DALAD2-0D
DY250-DALAD1-0D
DY250-DALAA4-0D
DY080-DALAD2-0D
DY080-DALAD1-0D
DY080-DALAA4-0D
DY050-DALAD2-0D
DY050-DALAD1-0D
DY050-DALAA4-0D
DY040-DALAD2-0D
DY040-DALAD1-0D
DY040-DALAA4-0D
DY025-DALAD2-0D
DY025-DALAD1-0D
DY025-DALAA4-0D
DY015-DALAD2-0D
DY015-DALAD1-0D
DY015-DALAA4-0D
DY250-DALAA2-0D
DY250-DALAA1-0D
DY250-DALAJ40-0D
DY250-DALAJ2-0D
Yokogawa DY Vortex flowmeter DY015
Yokogawa DY Vortex flowmeter DY015
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报