Product overview
MTL5526 2 channel switch operated relay isolated barrier
MTL5526 2 channel switch operated relay isolated barrier
MTL5526 product specification as below for your reference.
MTL5526 2 channel switch operated relay isolated barrier
MTL4526 –
MTL5526 SWITCH-OPERATED RELAY 2–channel IS–output The MTLx526 enables two
separate IS circuits in a hazardous area to be contact controlled by one or two,
on/off, control signals in a safe area. Applications include the calibration of
strain–gauge bridges; changing the polarity (and thereby the tone) of an IS
sounder; the testing of IS fire alarms; and the transfer of safe-area signals
into an annunciator with IS input terminals not segregated from each other. The
output–relay contacts are certified as non–energy–storing apparatus, and can be
connected to any IS circuit without further certification, provided that
separate IS circuits are such that they would remain safe if connected
together.
SPECIFICATION
MTL5526 2 channel switch operated relay isolated barrier
See also common
specification
Number of
channels
Two, fully
floating
Location of
control circuit
Safe area
Input/output
characteristics
Contact/Logic
mode
(Inputs
suitable for switch contacts, an open–collector transistor
or logic drive)
Relay energised
if < 450Ω or < 1V applied
Relay
de–energised if > 5kΩ or > 2V applied (35V max.)
Loop powered
mode
Relay energised
if >20V
Relay
de-energised if <17V
Power supply
failure protection
Relays
de–energised if supply fails
Response time
25ms nominal
Contacts
(suitable for connection to IS circuits)
1–pole
changeover per channel
Contact rating
250V ac,
limited to 40V dc for IS applications, 2A
(reactive loads
must be suppressed)
Contact life
expectancy
2 x 107
operations at maximum IS load
Relay drive
(see switch setting table)
Choice of
"loop-powered" or "contact/logic" control, for both
channels, by
switch selection. A further switch option ("1in2out")
enables either
input, in contact/logic mode, to activate both
outputs.
LED indicators
Green: power
indication
Yellow: two:
output status, on when relay energised
Power
requirement, Vs
41mA at 20V dc
44mA at 24V dc
60mA at 35V dc
Power
dissipation within unit
1.1W maximum at
24V
Safety
description (each channel)
Non-energy–storing
apparatus: relay contacts may be connected
to any IS
circuit without further consideration
Other related models for MTL5500 range as below for your reference.
MTL5526 2 channel switch operated relay isolated barrier
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599
MTL5526 2 channel switch operated relay isolated barrier
If you have any other question, please be free to contact me here!
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报