Product overview
MTL5018AC safe barrier Switch/proximity detector interface
MTL5018AC safe barrier Switch/proximity detector interface made in England
MTL5018AC product specification as below
MTL5018AC safe barrier Switch/proximity detector interface
MTL5018AC SWITCH/ PROXIMITY DETECTOR
INTERFACE two-channel, with line fault detection and phase reversal
The MTL5018ac enables two safe-area loads
to be controlled by two switches or proximity detectors located in a hazardous
area. Two relay outputs are provided. Independent phase reversal control allows
an alarm condition to be signalled for either state of the sensor. A selectable
line fault detect (LFD) facility detects an open or short circuit in either
field circuit.
SPECIFICATION
MTL5018AC safe barrier Switch/proximity detector interface
Number
of channels :Two
Location
of switches
Zone 0, IIC, T4–6 hazardous area Div. 1,
Group A hazardous location
Safe-area
output: Two relays with
changeover contacts
Hazardous-area
inputs: Inputs
conforming to NAMUR/DIN 19234 standards for proximity detectors
Voltage
applied to sensor :7 to 9V from 1kΩ ±10%
Input/output
characteristics:Normal (reverse) phase: output energised (de-energised) if Iin
>2.1mA or Rin 10kΩ Hysteresis: 200μA, typica
Line
fault detection (LFD)
User-selectable via switches on the top of
the unit. Line faults are indicated by an LED for each channel. A detected line
fault de-energises the relay.
Open-circuit alarm on if Iin 250μA
Short-circuit alarm on if Rin 360Ω Note: Resistors must be fitted when using
the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to
25kΩ in parallel with switch
Phase
reversal: Independent for each channel, user-selectable
Relay
type :Single pole, changeover contacts
Note: reactive loads must be adequately
suppressed
Relay
characteristics
Response time: 10ms maximum
Contact rating: 250V ac, 2A, cosø >0.7
40V dc, 2A, resistive load
LED
indicators
Green: power indication Yellow: two: status
of each channel (on when outputs are energised)
Red: two: LFD indication for each channel
(on when line fault detected)
Maximum power dissipation:<2.5W
Isolation 250V ac or dc between power supply, hazardous-area circuits and
relay outputs
Safety
description (each channel) 10.5V, 800Ω, 14mA, Um=
250V rms or dc
Power
Supply :85 to 265V ac 45 to 65 Hz
Other related models for MTL5500 range as below for your reference.
MTL5018AC safe barrier Switch/proximity detector interface
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599
MTL5018AC safe barrier Switch/proximity detector interface
If you have any other question about MTL MTL5018AC, please feel free to contact me here!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报