您所在位置:易展国际 > 展馆展区 > Textile & Leather Machinery  > Nonwoven Machinery > Standard Industrial Ovens

Standard Industrial Ovens

Product Price: Wage Negotiable
  • Product Model:
  • Brand: Hongzhan
  • Manufacturer: Hongzhan
  • Region: 北京丰台
  • Issuing Date: 2018-09-02
  • Visit: 12822
View
Introduction
Standard Industrial Ovens Ovens with high temperatures of 200, 300°C
Product Details

PV vertical precision oven, high temperature oven, oven, high temperature oven, oven, precision hot air circulation oven, oven

Industrial Ovens



 

The characteristics of equipment:

* equipment characteristics
High strength and high reliability of the structure design to ensure the high reliability of equipment;
The studio material is SUS304 stainless steel corrosion resistance, thermal fatigue, strong function, long service life;
Superfine glass fiber insulation material - that minimizes heat loss;
Surface spray treatment - ensure lasting anticorrosion function and appearance of the life of the equipment;
To ensure the high sealing equipment gate high temperature silicone rubber seal -;
A variety of optional features (car, test hole, recorder, ventilation etc.) to ensure the needs of users of various functions and test;
The door with the heater / fan interlock function (optional), material can be in and out of the temperature field distribution is reduced to a minimum;
* can be customized according to user requirements size / index / custom customized matching function
The highest temperature limit of 300 DEG C * optional
* temperature control
Can achieve the temperature constant control and program control (optional), horizontal / vertical optional air supply mode, to ensure the customer actual load temperature indicators when used to achieve the optimal effect;
With a sheathed heating tube as the heating source (no redness, no fire, easy to replace), greatly improves the safety and reliability of the equipment;
Each motor is configured over current protection (overheating) / heater set short-circuit protection, ensure the high reliability of air and heating equipment during operation;
Blast heating and interlock function and independent temperature protection function, prevent dry burning or temperature runaway dangerous equipment;
The electronic key parts adopt international famous brand products, the overall quality of the equipment has been improved and guaranteed;
* meet the following standard equipment
The condition of JB/T 5520-1991 drying box
GB/T 2423.2-2008 environmental testing for electric and electronic products part second: Test methods - Test B: high temperature
The method of environmental test for GJB 150.3A-2009 military equipment test chamber (high temperature test)
 


PV series Vertical precision oven The main technical indicators

Model
PV91
PV216
PVH91
PVH216
Nominal volume ( rise )
Ninety-one
Two hundred and sixteen
Ninety-one
Two hundred and sixteen
nature
can
*
One
temperature range
( ambient temperature + Twenty C ) To 200 C
( ambient temperature + Twenty C) To 300 C
Temperature fluctuation
Less than or equal to One hundred C: + 0.2 C = Two hundred C : . Zero point four C
Less than or equal to Two hundredC : . Zero point six C
Temperature deviation
. Two C
. Three C
Heating time
(ambient temperature +20 ~) Two hundred CBelow: 40min
(ambient temperature +20 ~) Two hundred C Below: 60min
The internal size (W * H * D mm)
W450 * H450 * D450
W600 * H600 * D600
W450 * H450 * D450
W600 * H600 * D600
The external dimensions (W * H * D mm * 2)
W620 * H1050 * D775
W770 * H1200 * D925
W620 * H1050 * D775
W770 * H1200 * D925
The use of environmental temperature
Forced air circulation and ventilation
Temperature regulating methods
0 ~ 40 C
constitute
Shell
Double sided galvanized steel plate, surface spray treatment
The inner body
SUS304 stainless steel plate
Heat insulation
glass fibre
heater
Ni Cr alloy electric heater
Fan
Centrifugal fan 120W 1
Centrifugal fan 120W 1
Damper
Manual switching cycle / ventilation state (throttle opening adjustable)
Controller
operation
Program operation, fixed value operation
Set the display range
(0 ~ 210&310) C
Display resolution
Temperature: 1 C Time: 1min.
Operation interface
Key setting mode
Program function
Two A memory program, a total of 16 steps, the temperature and time, to ensure the function, function of cycle operation
control mode
PID
input
PT100 Platinum resistance
Subsidiary function
The input line detection function, upper and lower temperature overheat alarm function, buzzer alarm function, automatic temperature overheat preventing function, abnormal display, alarm number display, self diagnosis function, temperature time guarantee function, after the power recovery action selection function, power failure protection function
The weight (kg)
One hundred and fifty
One hundred and seventy
One hundred and sixty
One hundred and eighty
The maximum power (kw)
Two
Two point seven
Two point seven
Three point eight
Standard configuration
The sample holder of 2 sets of 4 casters (2 casters, castors fixed 2), the sample power control terminals 1, 3 core (single-phase grounding +) power line (6 meters long) 1, fuse 3A 2, pin hole plug and lid 1.
Power Supply
AC220 + 10 %V 50 + 0.5Hz single phase
AC220 + 10%V + 0.5Hz - 50
Safety device
With leakage circuit breakers, temperature fuse, temperature switch, fan control circuit short circuit protection fuse, upper and lower temperature alarm power
Optional
Lead hole (diameter of 50/ with 80 / 100 / 120mm)
The lead rubber plug hole (diameter of 50/ with 80 / 100 / 120mm, with wire holes)
The sample frame and frame, frame and frame, with heavy samples increase the type inner box and chassis, timers, temperature recorder
The emergency stop switch, EBUS remote monitoring operation, external alarm output terminal, exhaust flange, stainless steel exhaust pipe
The power supply voltage (AC100V/AC200V) 3.
 
* One room temperature +25 C, circulation, no sample is measured under the condition of data.
* Two Not including the contour bulge.
 
 
Technical data of this material are subject to change without notice. Guangdong Hongzhan Technology Co. Ltd.
 
 
Telephone: 0769-83730866 Fax: 0769-83730860 Date of publication: Two thousand and thirteen yearSix month

Model
PV324
PV512
PVH324
PVH512
Nominal volume ( rise )
Three hundred and twenty-four
Five hundred and twelve
Three hundred and twenty-four
Five hundred and twelve
nature
can
*
One
temperature range
( ambient temperature + Twenty C ) To 200C
( ambient temperature + TwentyC ) To 300 C
Temperature fluctuation
Less than or equal to One hundred C: + 0.2C = Two hundred C : . Zero point four C
Less than or equal to Two hundred C : . Zero point six C
Temperature deviation
. Two C
. Three C
Heating time
(ambient temperature +20 ~) Two hundredC Below: 40min
(ambient temperature +20 ~)Two hundred C Below: 60min
The internal size (W * H * D mm)
W600 * H900 * D600
W800 * H800 * D800
W600 * H900 * D600
W800 * H800 * D800
The external dimensions (W * H * D mm * 2)
W770 * H1500 * D925
W1000 * H1400 * D1143
W770 * H1500 * D925
W1000 * H1400 * D1143
The use of environmental temperature
Forced air circulation and ventilation
Temperature regulating methods
0 ~ 40 C
constitute
Shell
Double sided galvanized steel plate, surface spray treatment
The inner body
SUS304 stainless steel plate
Heat insulation
glass fibre
heater
Ni Cr alloy electric heater
Fan
Centrifugal fan 120W 1
Centrifugal fan 120W 2
Damper
Manual switching cycle / ventilation state (throttle opening adjustable)
Controller
operation
Program operation, fixed value operation
Set the display range
(0 ~ 210) C
Display resolution
Temperature: 1 C Time: 1min.
Operation interface
Key setting mode
Program function
Two A memory program, a total of 16 steps, the temperature and time, to ensure the function, function of cycle operation
control mode
PID
input
PT100 Platinum resistance
Subsidiary function
The input line detection function, upper and lower temperature overheat alarm function, buzzer alarm function, automatic temperature overheat preventing function, abnormal display, alarm number display, self diagnosis function, temperature time guarantee function, after the power recovery action selection function, power failure protection function
The weight (kg)
One hundred and ninety
Two hundred and twenty
Two hundred
Two hundred and thirty
The maximum power (kw)
Five point eight
Six point eight
Six point eight
Nine point eight
Standard configuration
The sample holder of 2 sets of 4 casters (2 casters, castors fixed 2), the sample power control terminals 1, 3 core (single-phase grounding +) power line (6 meters long) 1, fuse 3A 2, pin hole plug and lid 1.
Power Supply
AC380 + 10%V three-phase four wire + 50 + 0.5Hz protection wire
AC380 + 10 The three-phase four wire%V + 50 + 0.5Hz protection wire
Safety device
With leakage circuit breakers, temperature fuse, temperature switch, fan control circuit short circuit protection fuse, upper and lower temperature alarm power
Optional
Lead hole (diameter of 50/ with 80 / 100 / 120mm)
The lead rubber plug hole (diameter of 50/ with 80 / 100 / 120mm, with wire holes)
The sample frame and frame, frame and frame, with heavy samples increase the type inner box and chassis, timers, temperature recorder
The emergency stop switch, EBUS remote monitoring operation, external alarm output terminal, exhaust flange, stainless steel exhaust pipe
The power supply voltage (AC100V/AC200V) 3.
 
* One room temperature +25 C, circulation, no sample is measured under the condition of data.
* Two Not including the contour bulge.
 
 
Technical data of this material are subject to change without notice. Guangdong Hongzhan Technology Co. Ltd.
 
 
Telephone: 0769-83730866 Fax: 0769-83730860 Date of publication: Two thousand and thirteen year Six month

Model
PV768
PV1000
PVH768
PVH1000
Nominal volume ( rise )
Seven hundred and sixty-eight
One thousand
Seven hundred and sixty-eight
One thousand
nature
can
*
One
temperature range
( ambient temperature + Twenty C ) To 200C
( ambient temperature + Twenty C) To 300 C
Temperature fluctuation
Less than or equal to One hundred C: + 0.2 C = Two hundred C : . Zero point four C
Less than or equal to Two hundredC : . Zero point six C
Temperature deviation
. Two C
. Three C
Heating time
(ambient temperature +20 ~) Two hundredC Below: 40min
(ambient temperature +20 ~) Two hundred C Below: 60min
The internal size (W * H * D mm)
W800 * H1200 * D800
W1000 * H1000 * D1000
W800 * H1200 * D800
W1000 * H1000 * D1000
The external dimensions (W * H * D mm * 2)
W1000 * H1800 * D1143
W1200 * H1600 * D1343
W1000 * H1800 * D1143
W1200 * H1600 * D1343
The use of environmental temperature
Forced air circulation and ventilation
Temperature regulating methods
0 ~ 40 C
constitute
Shell
Double sided galvanized steel plate, surface spray treatment
The inner body
SUS304 stainless steel plate
Heat insulation
glass fibre
heater
Ni Cr alloy electric heater
Fan
Centrifugal fan 120W 1
Centrifugal fan 120W 2
Damper
Manual switching cycle / ventilation state (throttle opening adjustable)
Controller
operation
Program operation, fixed value operation
Set the display range
(0 ~ 210) C
Display resolution
Temperature: 1 C Time: 1min.
Operation interface
Key setting mode
Program function
Two A memory program, a total of 16 steps, the temperature and time, to ensure the function, function of cycle operation
control mode
PID
input
PT100 Platinum resistance
Subsidiary function
The input line detection function, upper and lower temperature overheat alarm function, buzzer alarm function, automatic temperature overheat preventing function, abnormal display, alarm number display, self diagnosis function, temperature time guarantee function, after the power recovery action selection function, power failure protection function
The weight (kg)
Three hundred and twenty-five
Three hundred and fifty-five
Three hundred and thirty-five
Three hundred and sixty-five
The maximum power (kw)
Six point eight
Seven point eight
Eight point eight
Nine point eight
Standard configuration
The sample holder of 2 sets of 4 casters (2 casters, castors fixed 2), the sample power control terminals 1, 3 core (single-phase grounding +) power line (6 meters long) 1, fuse 3A 2, pin hole plug and lid 1.
Power Supply
AC380 + 10%V three-phase four wire + 50 + 0.5Hz protection wire
AC380 + 10 The three-phase four wire%V + 50 + 0.5Hz protection wire
Safety device
With leakage circuit breakers, temperature fuse, temperature switch, fan control circuit short circuit protection fuse, upper and lower temperature alarm power
Optional
Lead hole (diameter of 50/ with 80 / 100 / 120mm)
The lead rubber plug hole (diameter of 50/ with 80 / 100 / 120mm, with wire holes)
The sample frame and frame, frame and frame, with heavy samples increase the type inner box and chassis, timers, temperature recorder
The emergency stop switch, EBUS remote monitoring operation, external alarm output terminal, exhaust flange, stainless steel exhaust pipe
The power supply voltage (AC100V/AC200V) 3.
 
* One room temperature +25 C, circulation, no sample is measured under the condition of data.
* Two Not including the contour bulge.
 
 
Technical data of this material are subject to change without notice. Guangdong Hongzhan Technology Co. Ltd.
 
 
Telephone: 0769-83730866 Fax: 0769-83730860 Date of publication: Two thousand and thirteenyear Six month

相关产品
Send Message
  • Copyright2018 yi-z.com Corporation and its licensors.All Rights Reserved.
备案号:粤ICP备11010883号-17